5-15
2. Flange Back Check
Mode STILL
Subject Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point Check operation on TV monitor
Measuring Instrument
Specified value Focused at the TELE end and
WIDE end
Checking method:
1) Place the Siemens star 2.0 m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to the Si-
emens star up to a point before noise appear on the image.
3) Select page: 0, address: 01, and set data: 01.
4) Select page: 5, address: F1, and set data: FF.
5) Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
6) Perform Data setting during camera system adjustment.
(Refer to page 5-13)
7) Shoot the Siemens star with the zoom TELE end.
8) Turn on the auto focus.
9) Check that the lens is focused.
10) Select page: 6, address: 2C, and set data: 01.
11) While observe the TV monitor, change the zoom to the WIDE
end and check that the lens is focused.
Processing after completion of adjustment:
1) Select page: 6, address: 2C, and set data: 00.
2) Select page: 5, address: F1, and set data: 00.
3) Select page: D, address: 63, set data: 00, and press the PAUSE
button of the adjusting remote commander.
4) Release the data setting performed at step 6).
(Refer to page 5-13)
5) Select page: 0, address: 01, and set data: 00.

Table of Contents