Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-163-
P05.18
S4 terminal
switch-on delay
communication address is 0x200A.
0.000s
P05.19
S4 terminal
switch-off delay
0.000s
P05.20
HDIA terminal
switch-on delay
0.000s
P05.21
HDIA terminal
switch-off delay
0.000s
P05.22
HDIB terminal
switch-on delay
0.000s
P05.23
HDIB terminal
switch-off delay
0.000s
P05.24
Lower limit value
of AI1
These function codes define the relation between analog
input voltage and corresponding set value of analog input.
When the analog input voltage exceeds the range of
max./min. input, the max. input or min. input will be adopted
during calculation.
When analog input is current input, 0–20mA current
corresponds to 0–10V voltage.
In different applications, 100% of analog setting corresponds
to different nominal values.
The figure below illustrates several settings.
-100%
100%
Corresponding setting
AI
-10V
10V
20mA
0
AI2
AI1
Input filter time: Adjust the sensitivity of analog input,
increase this value properly can enhance the anti-
interference capacity of analog variables; however, it will
also degrade the sensitivity of analog input.
Note: AI1 can support 0–10V/0–20mA input, when AI1 selects
0–20mA input; the corresponding voltage of 20mA is 10V; AI2
supports -10V–+10V input.
Setting range of P05.24: 0.00VP05.26
Setting range of P05.25: -300.0%–300.0%
Setting range of P05.26: P05.24–10.00V
Setting range of P05.27: -300.0%–300.0%
Setting range of P05.28: 0.000s–10.000s
Setting range of P05.29: -10.00V–P05.31
Setting range of P05.30: -300.0%–300.0%
Setting range of P05.31: P05.29P05.33
Setting range of P05.32: -300.0%–300.0%
0.00V
P05.25
Corresponding
setting of lower
limit of AI1
0.0%
P05.26
Upper limit value
of AI1
10.00V
P05.27
Corresponding
setting of upper
limit of AI1
100.0%
P05.28
Input filter time of
AI1
0.030s
P05.29
Lower limit value
of AI2
-10.00V
P05.30
Corresponding
setting of lower
limit of AI2
-100.0%
P05.31
Intermediate
value 1 of AI2
0.00V
P05.32
Corresponding
setting of
intermediate value
1 of AI2
0.0%
P05.33
Intermediate
value 2 of AI2
0.00V
P05.34
Corresponding
setting of
intermediate
value 2 of AI2
0.0%
P05.35
Upper limit value
of AI2
10.00V
P05.36
Corresponding
setting of upper
limit of AI2
100.0%
P05.37
Input filter time of
AI2
0.030s