Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-222-
Setting range: 0–1000
P21.10
Detection time for
positioning
completion
0.01000.0ms
10.0ms
P21.11
Numerator of
position command
ratio
Electronic gear ratio, used to adjust the corresponding
relation between position command and actual running
displacement.
Setting range: 165535
1000
P21.12
Denominator of
position command
ratio
Setting range: 165535
1000
P21.13
Position
feedforward gain
0.00120.00%
For pulse train reference only (position control)
100.00
P21.14
Position
feedforward filter
time constant
0.03200.0ms
For pulse train reference only (position control)
3.0ms
P21.15
Position command
filter time constant
The position feedforward filter time constant during pulse
train positioning.
0.03200.0ms
0.0ms
P21.16
Digital positioning
mode
0x00000xFFFF
Bit0: Positioning mode selection
0: Relative position
1: Absolute position (home) (reserved)
Bit1: Positioning cycle selection
0: Cyclic positioning by terminals
1: Automatic cyclic positioning
Bit2: Cycle mode
0: Continuous
1: Repetitive (supported by automatic cyclic positioning
only)
Bit3: P21.17 digital setting mode
0: Incremental
1: Position type (do not support continuous mode)
Bit4: Home searching mode
0: Search for the home just once
1: Search for the home during each run
Bit5: Home calibration mode
0: Calibrate in real time
1: Single calibration
Bit6: Positioning completion signal selection
0: Valid during the time set by P21.25 (Hold time of
positioning completion signal)
1: Always valid
Bit7: Initial positioning selection (for cyclic positioning by
terminals)
0: Invalid (do not rotate)
0x0000