EasyManua.ls Logo

Sourcetronic ST600 - Page 230

Sourcetronic ST600
390 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-223-
1: Valid
Bit8: Positioning enable signal selection (for cyclic
positioning by terminals only; positioning function is
always enabled for automatic cyclic positioning)
0: Pulse signal
1: Level signal
Bit9: Position source
0: P21.17 setting
1: PROFIBUS/CANopen setting
Bit10: Whether to save the encoder pulse counting
value at power failure
0: Do not save
1: Save
Bit 11: Reserved
Bit12: Positioning curve selection (reserved)
0: Straight line
1: S curve
P21.17
Position digital
reference
Set digital positioning position;
Actual position=P21.17×P21.11/P21.12
0–65535
0
P21.18
Positioning speed
setup selection
0: Set by P21.19
1: Set by AI1
2: Set by AI2
3: Set by AI3
4: Set by high speed pulse HDIA
5: Set by high speed pulse HDIB
0
P21.19
Positioning speed
digits
0–100.0% max. frequency
20.0%
P21.20
Acceleration time
of positioning
Set the acceleration/deceleration time of positioning
process.
Acceleration time of positioning means the time needed
for the VFD to accelerate from 0Hz to the max. output
frequency (P00.03).
Deceleration time of positioning means the time needed
for the VFD to decelerate from the max. output frequency
(P00.03) to 0hz.
Setting range of P21.20: 0.01300.00s
Setting range of P21.21: 0.01300.00s
3.00s
P21.21
Deceleration time
of positioning
3.00s
P21.22
Hold time of
positioning arrival
Set the hold time of waiting when target positioning
position is reached.
Setting range: 0.000–60.000s
0.100s
P21.23
Home search
speed
0.0050.00Hz
2.00Hz
P21.24
Home position
offset
0–65535
0