Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-231-
P24.17
Pulse filer
processing
0x00000xFFFF
Bit0: Enable/disable encoder input filter
0: No filter
1: Filter
Bit1: Encoder signal filter mode (set Bit0 or Bit2 to 1)
0: Self-adaptive filter
1: Use P24.18 filter parameters
Bit2: Enable/disable encoder frequency-division output
filter
0: No filter
1: Filter
Bit3: Reserved
Bit4: Enable/disable pulse reference filter
0: No filter
1: Filter
Bit5: Pulse reference filter mode (valid when Bit4 is set
to 1)
0: Self-adaptive filter
1: Use P24.19 filter parameters
Bit615: Reserved
0x0033
P24.18
Encoder pulse
filter width
0–63
The filtering time is P24.18×0.25 μs. The value 0 or 1
indicates 0.25 μs.
2
P24.19
Pulse reference
filter width
0–63
The filtering time is P24.19×0.25 μs. The value 0 or 1
indicates 0.25 μs.
2
P24.20
Pulse number of
pulse reference
0–16000
1024
P24.21
Enable angle
compensation of
synchronous motor
0–1
1
P24.22
Switch-over
frequency threshold
of speed
measurement mode
0–630.00Hz
1.00Hz
P24.23
Synchronous motor
angle compensation
coefficient
-200.0200.0%
100.0%
P24.24
Number of pole
pairs in inital
magnetic pole angle
autotuning
1–128
2