Chapter 9: Ethernet Cards
Standard Ethernet Features
118 SmartBits System Reference
Captured-Data Status Codes
In SmartWindow and SmartLib, captured frames include the following status codes that
identify content quickly. In SmartWindow online help, refer to Capture Setup for further
details.
Note: Management frames such ARP/ICMP/IGMP frames are not given a special status
code.
Table 9-10. Capture Frame Status Codes
Code
SX-7210,
SX-7410
L3-6705,
L3-6710
ML-7710
GX-1405B,
LAN-3200A
LAN-3100A
POS Modules,
LAN-3201A
U Undersize Undersize Undersize Undersize Undersize Undersize
O Oversize Oversize Oversize Oversize Oversize Oversize
T Trigger N/A Trigger Trigger Trigger Trigger
C CRC CRC CRC CRC CRC CRC
A Alignment N/A Alignment N/A Alignment N/A
R N/A Receive
Overrun
N/A Run Disparity ARP Run Disparity
E N/A Framing Error N/A N/A N/A N/A
S N/A Signature Signature N/A N/A N/A
L N/A Collision N/A N/A Collision N/A
V N/A N/A VLAN Tag N/A VLAN Tag N/A
P N/A N/A N/A N/A Pause N/A
F N/A N/A N/A N/A IP Frame N/A
K N/A N/A N/A N/A IP Checksum IP Checksum
I Interframe
Gap
Subminimum
Interframe
Gap
Subminimum
Interframe
Gap
Subminimum
Interframe
Gap
Subminimum
Interframe
Gap
Subminimum
Interframe
Gap
Subminimum
D N/A N/A N/A N/A N/A Data Integrity
Error

Table of Contents