Chapter 13: Token Ring Cards
Token Ring Counters
174 SmartBits System Reference
TokenRingCounters
The counters can hold a maximum of 2
32-1
counts before cycling. All counters can
display either rates or events. The Token Ring port counter window in SmartWindow can
display only 10 counters at a time; the default counters are:
Transmit Packet Counter.
Receive Packet Counter.
FCS Error Counter.
Oversize Packet Counter.
Undersize Counter.
Bytes Received Counter.
Trigger Counter.
MAC Frame Counter.
Abort Frames Counter.
Token Rotation Time.
Additional available counters are error counters derived from decoding MAC frames:
Line Errors.
Internal Errors.
Burst Errors.
A/C Errors.
Abort Errors.
Lost Frame Receiver Congestion.
Frame Copied, Frequency Errors.
Token Errors.
Purge Events.
Beacons.
Claim Events.
Insertions.
All undisplayed counters are continuously active and can be chosen at any time without
affecting their contents.

Table of Contents