Chapter 11: ATM Cards
ATM Line Event Statistics
SmartBits System Reference 155
ATMLineEventStatistics
Applications
Supported:
SmartWindow, SmartLib.
Under SmartWindow, you can view line error events (either in Smartcounters or by
selecting an ATM card and selecting the Display Counters command).
Card Types: SeespecificATMcardtopics.
Line Event Statistics for AT-9015 and AT-9020 SmartCards
SmartWindow provides these line event statistics for the AT-9015 DS1 and AT-9020 E1
SmartCards.
To access these statistics, select the following Line tabs on the Statistics window:
• Code Violation. The total number of line code violations. For AT-9015 DS1 and for
AT-9020 E with B8ZS line encoding, this counter contains the number of bipolar
violations plus the number of times that 8 consecutive zeros are received. It counts
consecutive bipolar violations of the same polarity with HDB3 coding.
• Frame Error. The counter only counts when the card is operating in a non LOS
condition.
– For DS1 ESF framing mode. The total number of CRC-6 errors.
– ForE1framingmodes.ThenumberofCRC-4errorsthatoccur.
• Sync Error. For AT-9015 DS1 only. The total number of multiframes out of
synchronization.
• FEBE Error. For AT-9020 only. The total number of Far End Block errors received.
This counter increments every time the E-bit is set to 0 in frames 13 and 15.
• PLCP OOF Error. The total number of Physical Layer Convergence Protocol out of
frame errors. This counter statistic is active in the DS1 PLCP and the E1 PLCP
mapping modes only.
• PLCP Frame Error. For DS1 PLCP and the E1 PLCP mapping modes only. The
total number of PLCP framing errors.
• PLCPL BIP Error. For DS1 PLCP and the E1 PLCP mapping modes only. The total
number of detected PLCP Bit Interleaved Parity errors.
• PLCP FEBE Error. For DS1 PLCP and the E1 PLCP mapping modes only. This
counter is active in the DS1 PLCP and the E1 PLCP mapping modes only.