MULTIPLE TRIGGER EVENTS DURING SPRAY
If the system receives mulple start events before the spray cycle is nished, they will be added to a queue and
executed according to the given delay mes.
OVERLAPPING SPRAY EVENTS
If spray events overlap, the overlapping event will be ignored, and the system will connue to spray to ensure the
objects are sprayed correctly. This situaon may occur when the following is true:
Stop delay > Start delay
Delay between two objects < (stop delay - start delay)
Variable spray period—mulple triggers