EasyManua.ls Logo

Spraying Systems AUTOJET 1750+ - Page 25

Spraying Systems AUTOJET 1750+
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
MULTIPLE TRIGGER EVENTS DURING SPRAY
If the system receives mulple start events before the spray cycle is nished, they will be added to a queue and
executed according to the given delay mes.
OVERLAPPING SPRAY EVENTS
If spray events overlap, the overlapping event will be ignored, and the system will connue to spray to ensure the
objects are sprayed correctly. This situaon may occur when the following is true:
Stop delay > Start delay
Delay between two objects < (stop delay - start delay)
Variable spray period—mulple triggers
Variable Spray Period – Overlapping Triggers

Other manuals for Spraying Systems AUTOJET 1750+