OBJECTS TOO SMALL
If spray events overlap, the overlapping event will be ignored, and the system will skip the small object.
This situaon may occur when the following is true:
Stop delay < Start delay
Object size < (start delay - stop delay)
DISTANCE DELAY, MAXIMUM SPRAY PERIOD
This ming mode is used to create a delayed spray pulse of an unknown period when receiving a trigger signal.
The start and stop delays are typically the distance between the object sensor and the spray nozzle.
The spray period is limited in me to the congured spray period.
In this ming mode, the repeat funconality works in me units.
Variable spray periodsmall objects
Distance delay, max. spray period
Variable Spray Period—Objects too small