4-3
Category Splice Program
Details
Auto
SM G652 Auto
Can be used for splicing identical SMF (ITU-T G.652).
MM G651 Auto
Can be used for splicing identical MMF (ITU-T G.651).
NZ G655 Auto
Can be used for splicing identical NZDSF (ITU-T G.655) or identical DSF
(ITU-T G.653)
BIF G657 Auto
Can be used for splicing identical BIF (ITU-T G.657).
About Auto Arc Power
In Auto mode, the T-400S has the function to analyze an arc and calibrate the arc condition automatically at
each splice. Therefore, most of times, an arc test is not needed in Auto mode.
Perform an arc test in the following situations to calibrate the arc power and position.
• Poor splice performance (high or inconsistent splice losses, poor splice strength)
• After electrode replacement
• Extreme changes in temperatures, humidity or air pressure
Please perform an arc test before splicing on all splice programs except Auto mode.
Category Splice Program
Details
Recent
-
The splice program selected recently is listed.
SMF G652
SM G652 Std.
Can be used for splicing identical standard SMF (ITU-T G.652).
SM G652 Quick
Can be used for splicing identical standard SMF (ITU-T G.652) and making
a faster splice.
E-SC Fusion Can be used for splicing Sumitomo E-SC Fusion Connector.
SM G652 Drop
Can be used for splicing rectangular drop cable. A proof test is started
automatically after splicing. Re-arc function is not available.
MMF G651
MM G651 Std.
Can be used for splicing identical standard MMF (ITU-T G.651).
MM G651 Quick
Can be used for splicing identical standard MMF (ITU-T G.651) and making
a faster splice.
NZ G655/
DS G653
NZ G655 Typ.
Can be used for splicing identical standard NZDSF (ITU-T G.655) or iden-
tical standard DSF (ITU-T G.653)
NZ G655 Quick
Can be used for splicing identical standard NZDSF (ITU-T G.655) or iden-
tical standard DSF (ITU-T G.653) and making a faster splice.
<Auto mode>
<Other splice programs>
Splice programs