SUNFAR C300 25
C300 series of non-sensor current vector-control inverter manual
Parameters’
Types
Function Code Name Setting range
Minimum
Setting
Manufacture
Setting
Modify
Limit
F2.7
External freq. set time
constant offiltering
0.01~1.00Sec 0.01 0.10
F2.8 Combination setting mode Refer to the explanations about(0~19) 1 0
F2.9
Analog output selection
(AVO)
The first part of LED (form right to left):
AO1output
0:Output freq.
1:Output current
2:Output voltage
3:Rotational speed Of applied motor
4:PID setting
5:PID feedback
The second and third and fourth part of
LED:Reserved
1 0000
F2.10
The lower limit of analog
output AVO
0.0~[F2.11] 0.1 0.0 V
F2.11
The upper limit of analog
output AVO
[F2.10]~12.0 0.1 10.0V
Analog I/O parameter unit
F2.12 Reserved
--
-- --
--
-- -- --