SINGLE PHASE HI 10/12kW | User Manual26
Wiring System for Inverter
E-BAR
E-BAR
AC Breaker
AC Breaker AC Breaker
Load
L L
N
PE
N
PE
Battery
Diesel
generator
Diesel
generator
BMS
Load
L N PE
Grid
L L
N
PE
N
PE
Grid
CT
CT
Home Loads
Hybrid Inverter
AC Breaker
DC Breaker
PV
DC Breaker
E-BAR
E-BAR
N-BAR
AC Breaker
AC Breaker AC Breaker
Load
L L
N
PE
or
N
PE
Battery
PV
BMS
Load
L N PE
Grid
L L
N
PE
N
PE
Grid
CT
CT
Home Loads
Hybrid Inverter
AC Breaker
DC Breaker
DC Breaker
Do not connect this terminal
when the neutral wire and PE
wire are connected together.
E-N
Link
This diagram is an example for application that Neutral connects together
with PE in distribution box.
Such as: Australia, New Zealand, South Africa, etc. (Please follow local
wiring regulations!)
This diagram is an example for grid systems without special requirements
on electrical wiring connection.
Note: The back-up PE line and earthing bar must be grounded properly
and effectively.
Otherwise the back-up function may be abnormal when the grid fails.