EasyManua.ls Logo

SUNWARD SWE90UF-2PB - Air Filter; Cooling System

SUNWARD SWE90UF-2PB
183 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SWE90UF-2PB Operation & Maintenance Manual
107
Maintenance is needed only for the initial inspection.
When the machine is delivered from SUNWARD, water and long lifetime cooling water
have been filled in the cooling system. You can replace the cooling water after a year or
every 2000 hours operation if SUNWARD’s genuine cooling water is always used.
When the machine is used in the dusty area, maintenance interval should be shortened.
Non-Amine Engine Coolant (FD-2B HEC-II-40) (Sunward genuine) is the recommended
coolant.
5.4.6 Air Filter
Parts name
Qty.
Interval (hours)
8
50
100
250
500
1000
2000
1
Outer element of
air filter
Clean
1
Replace
1
2Inner element of
air filter
Replace
1
3. Connection
pipelines
between air
filter and
engine
Check Seal
Replace
When pipeline has crack and air leakage, replace it in
time.
5.4.7 Cooling System
Parts name
Qty.
Interval (hours)
8
50
100
250
500
1000
2000
1. Check level of cooling water
1
2. Check and adjust fan belt
tension
1
※1
3. Replace cooling water
4.2L
△※2
4. Clean radiator
1
△※3
5. Clean condenser of air-
conditioner (optional)
1
△※3

Table of Contents