7. Oil filter: When oil filter clogging alarm switch connects, 5 seconds later, corresponding icon will be
displayed in warning indicating area; the red indicator light will be on and the buzzer will be activated.
8. Charging indication: When generator stopped, corresponding label and description will be displayed in
monitor.
9. Pre-heat indication: Input 12V power supply, the indicator lights of preheating will be on. And description
will be displayed.
3.3.3 Buttons
As shown in FIG. 3.3.2, the five buttons of the first line under monitor, their functions will be displayed on
the monitor. Different description is for different functions. If the description is blank, that means
corresponding button is useless at present.
By operating buttons, the monitor will display information as water temperature, oil temperature, oil
pressure, oil level, model, edition of software and warning values; engine tooth is controllable by buttons.
F1 meter settings
F2 check machine parameters
F3 machine auto-idle (on/off) button
F4 Mode selection button
F5 Machine fault code/serial no.
Users may change time and stage hour meter by entering the user’s setting interface. The initial code is