to be stored outdoors, select level, firm ground and
cover the machine with a sheet.
2.2.2 During Storage
Note
When it's necessary to perform the
rust-preventive operation whilethe machine is at
indoor, open the doors and windows to ventilate
and prevent gas poisoning.
During storage, operate the machine to travel, swing
and dig for 2 to 3 cycles at least once a month so as to
lubricate machine, and charge the machine battery.
Before operating, check cooling water level and
lubrication status.
Air condition must run once a month.
2.2.3 After Storage
Note
Start engine only in well-ventilated condition.
Remove lubricating grease on piston rod surface.
Apply grease to all lubricating parts.
Check engine oil level, keep it in specified level, if not,
and refill engine oil. If some water is found to mix in the
oil, replace it.
Check fuel level and bleed the air.
Check its level to ensure that it is with the standard
range.
Start and run the engine at half speed for several
minutes before operation with full load.
Cycle all hydraulic function for several times.

Table of Contents