18
※Opening Mode
-Temporary Open: When the door is open, it is automatically closed after a specific time.
-Toggle: The door is opened after the first authorization success and it remains unlocked
until the second authorization success.
1.4.5 Configuring environment settings
Settings for date and time: Set the values as “3.1 Date, Time.”
Fingerprint authorization related settings: Set the values after reading the case of
fingerprint selection in “4.1 Authorization.”
Operation mode setting: Finish the setting after seeing the operation mode
selection case in “4.1 Authorization.”
※Sync. Button
(In case of using Secure I/O)
Sync. button should be pressed when Relay
setting is completed.
Enter the time and
press OK.
*The time is set for
automatically closing the
door after the specified
time.
Use ◀/▶ buttons to
select Not Use for Held
Open Alarm and press
OK.
*Not Use/Sound/Backlight/
Sound & Light/SIO Relay0/
SIO Relay1
Door Sensor
SIO Input 1
SIO Relay 0
Held Open Alarm
Not Use
Door
Use ◀/▶ buttons to
select N.O and press
OK.
Use ◀/▶ buttons to
select SIO Input 1 and
press OK.
*Not Use/ SIO Input0/ SIO
Input1
Opening Mode
Temporary Open
Door
Use ◀/▶ buttons to
select Temporary Open
for opening mode and
press OK.
* Temporary Open/Toggle
Type
N.O
Door Sensor
Open Time(sec)
3
Door
Use ◀/▶ buttons to
select Not Use for
Forced Open Alarm and
press OK.
*Not Use/Sound/Backlight/
Sound & Light/SIO Relay0/
SIO Relay1
The completion message
window appears.
Forced Open Alarm
Not Use
Door
Complete
When you exit from the menu before completing the relay setup, the
configuration is not stored so please finish configuration until the
message “Complete” appears.