17
Cont.
1.4.4 Configuring Secure I/O
This connects BioLite Net to Secure I/O.
1. Connect wires between BioLite Net, Secure I/O, and respective switches as shown
below.
2. Configure the relay settings as shown below. (Based on the figure above)
For actual wiring, see “6.4 System Installation.”
Follow the instructions below only when the dedicated PC software is not
used. When using the software, refer to the software manual.
Use ◀/▶ buttons to
select SIO Relay 0 and
press OK.
Use ◀/▶ buttons to
select SIO Relay 0 and
press OK. (*Not Use/ SIO
Input 0/ SIO Input 1)
Relay
SIO Relay 0
Door
Exit Button
SIO Input 0
SIO Relay 0
Use ◀/▶ buttons to
select N.O and press
OK.
Type
N.O
Exit Button
Device
In/Out
Use ◀/▶ buttons to
select the In/Out icon
and press OK.
Press Menu -> Enter ID ->
Enter password ->Use◀/▶
buttons to select the
Device icon and press OK.
Item
Door
In/Out
Use ◀/▶ buttons to
select Door and press
OK.