71
NOTE:
• The station to which SDS was connected is regis-
tered as the master BCM. If SDS is connected to
the BCM of the second station and the system is
calibrated, the BCM of the second station serves
as the master BCM.
• If the “Cancel” button is clicked or the “Esc” key is
pressed during system calibration, the window
shown at right appears. Click the “OK” button to
calibrate the system. To continue system calibra-
tion, click the “Cancel” button.
(4) The following window appears. This window is used to register the system configuration.
In this window, select the number of stations and the number of engines by clicking the button, click
the “OK” button, and proceed to the next step.
(Keyboard) Move to a desired item by using the “Tab” key. Select a desired item by using the “Up” or
“Down” arrow key and press the “Enter” key to have the selected item accepted.
Clicking the “Cancel” button cancels system calibration.
NOTE:
If you make a selection different from the actual
configuration, the error screen is displayed.