5. Fuel Injection System
5-54
3. FREEZED DATA
Objective: When a sensor fault, the EMS system will record all the parameters of fault signals, in
order to facilitate fault diagnosis.
In the directory functions used "" "" button, select "FREEZED DATA" project, press the "ENTER"
key to the implementation.
Only one page, at any screen, press the "EXIT" button, the function can return to the directory screen.
In the "FREEZED DATA" of the screen use "" "" button to move the left side of the project ""
symbol selected items, press the "ENTER" buttom lock of the project, and press the "F4" button
showed that the wave of projects.
Able to use " left" and "right " button, can transform View wave numerical size.