RS-232 Interface 8 - 5
RS-232 Host Parameters (continued)
Selecting the ICL, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, Olivetti, Omron, OPOS/JPOS, Fujitsu or CUTE
host type enables the transmission of code ID characters listed in Table 8-3. These code ID characters are not
programmable and are separate from the Transmit Code ID feature. Do not enable the Transmit Code ID feature
for these terminals.
Table 8-3
Terminal Specific Code ID Characters
Code Type ICL
Wincor-
Nixdorf
Mode A
Wincor-
Nixdorf
Mode B
Olivetti Omron
OPOS/
JPOS
Fujitsu CUTE
UPC-A A A A A A A A
A
UPC-E E C C C E C E
None
EAN-8/JAN-8 FF B B B FF B FF
None
EAN-13/JAN-13 F A A A F A F
A
Code 39 C <len> M M M <len> C <len> M None
3
Code 39 Full ASCII None M M None None M None
3
Codabar N <len> N N N <len> N <len> N None
None
Code 128 L <len> K K K <len> L <len> K None
5
I 2 of 5 I <len> I I I <len> I <len> I None
1
Code 93 None L L L <len> None L None
None
D 2 of 5 H <len> H H H <len> H <len> H None
2
GS1-128 L <len> P P P <len> L <len> P None
5
MSI None O O O <len> None O None
None
Bookland EAN F A A A F A F
None
Trioptic None None None None None None None
None
Code 11 None None None None None None None
None
IATA H<len> H H None None H None
2
Code 32 None None None None None None None
None
GS1 Databar Variants None E E None None None None
None
PDF417 None Q Q None None None None
6
Datamatrix None R R None None R None None
Micro PDF None S S None None S None None
Maxicode None T T None None T None None
QR Codes, Macro QR
and Micro QR
None U U None None U None None
Aztec/Aztec Rune None V V None None V None None

Table of Contents