EasyManua.ls Logo

Takeuchi TB215R - Spanner Cylinder Does Not Move or Lacks Force

Takeuchi TB215R
303 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
5
SPANNER
TROUBLESHOOTING
5G8AX001SPANNER
Spanner
Spanner cylinder does not move or lacks force
1
Check
the operation of
actuators other than the
spanner cylinder
Normal
2
Check
the spool opera-
tion
Faulty
Repair
orr
eplace
thehousing
block
Normal
3 Check
thelinkage
Faulty
Adjust, r
epair or replace
Normal
4
Check
the supply pres-
sure of the control valve
Faulty
Repair
orr
eplace
thehousing
block
Normal
5 Check the swivel joint
Faulty
Repair
or replace the swivel
joint
Normal
Spanner cylinder is faulty
Repair
or replace the spanner
cylinder
Switching
 between the blade cylinder operation and the
spannercylinderoperationcanbedonebyoperatingthe
lever
.
Ther
efore,
checkingpr
ocedure
forthespannercylin
-
der is similar to that for the blade cylinder.
ī˜ƒā€œ5.Troubleshooting,Dozerbladeā€
1.
C
heck
the operation of actuators other than the
spanner cylinder.
2.
C
heck the spool operation.
ī˜ƒā€œ5.Troubleshooting,Traveling,Rightorlefttravelis
impossible, 2. Check the spool operationā€
3. Check the linkage.
ī˜ƒā€œ5.Troubleshooting,Traveling,Rightorlefttravelis
impossible,3.Checkthelinkageā€
4. Check the supply pressure of the control valve.
Disconnect
one of the hoses connected to the control
valve
housingblock(spanner).Fitthepr
essure
gauge
tothehosejustdisconnected.Operatethelever(span
-
ner)
andcheckthesupplypr
essure
ofthevalve.

ā€¢ī˜ƒ If
the value indicatedisnot as below
,
the housing
block is faulty.

 Supply
pr
essure:

20
.0MPa(2900PSI)

Table of Contents

Other manuals for Takeuchi TB215R

Related product manuals