1
5
SPANNER
TROUBLESHOOTING
5G8AX001SPANNER
Spanner
Spanner cylinder does not move or lacks force
1
Check
the operation of
actuators other than the
spanner cylinder
Normal
2
Check
the spool opera-
tion
Faulty
Repair
īorīr
eplace
ītheīhousingī
block
Normal
3 Check
ītheīlinkage
Faulty
Adjust, r
epair or replace
Normal
4
Check
the supply pres-
sure of the control valve
Faulty
Repair
īorīr
eplace
ītheīhousingī
block
Normal
5 Check the swivel joint
Faulty
Repair
or replace the swivel
joint
Normal
Spanner cylinder is faulty
Repair
or replace the spanner
cylinder
Switching
ī betweenī theī bladeī cylinderī operationī andī theī
spannerīcylinderīoperationīcanībeīdoneībyīoperatingītheī
lever
.
īTher
efore,
īcheckingīpr
ocedure
īforītheīspannerīcylin
-
der is similar to that for the blade cylinder.
īā5.īTroubleshooting,īDozerībladeā
1.
C
heck
the operation of actuators other than the
spanner cylinder.
2.
C
heck the spool operation.
īā5.īTroubleshooting,īTraveling,īRightīorīleftītravelīisī
impossible, 2. Check the spool operationā
3. Check the linkage.
īā5.īTroubleshooting,īTraveling,īRightīorīleftītravelīisī
impossible,ī3.īCheckītheīlinkageā
4. Check the supply pressure of the control valve.
Disconnect
one of the hoses connected to the control
valve
īhousingīblockī(spanner).īFitītheīpr
essure
īgaugeī
toītheīhoseījustīdisconnected.īOperateītheīleverī(span
-
ner)
īandīcheckītheīsupplyīpr
essure
īofītheīvalve.
ī
ā¢ī If
ītheī valueī indicatedīisīnotī asī below
,
ītheī housingī
block is faulty.
ī
ī Supply
īpr
essure:
ī
20
.0īMPaī(2900īPSI)