EasyManua.ls Logo

TallyGenicom Matrix Printer - Device Status Report (DSR)

TallyGenicom Matrix Printer
409 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Device Status Report (DSR) CSI ... n
Data Structure ASCII CSI n "n" [B] device status report
hex. 9B n 6E
dec. 155 n 110
Description For n the following parameters are available:
n hex. dec. status report direction
0 30 48 “Ready, no malfunction” printer computer
1 31 49 “Busy, no malfunction” printer computer
3 33 51 “Some malfunction detected” printer computer
5 35 53 Request of device status report computer printer
By these sequences it is possible to request the current printer status.
This sequence can only be used if the printer is connected to the computer with a serial
interface or a other bi-directional interface.
The printer sends the complete sequence back to host with parameters 0, 1 or 3.
92 Miscellaneous

Table of Contents

Related product manuals