119
[SOURce]:POWer:STATe <Bool>
Function
Enables/Disables the constant power limit mode.
Parameters
0|1, OFF|ON
Query
[SOURce]:POWer:STATe?
Return
<Bool> 0|1
NOTE:
Analog programming, internal resistance & sequencer functions should be disabled to enable
Constant Power.
[SOURce]:POWer[:LEVel] <NRf+>
Function
Sets the constant power limit level.
Parameters The range is limited to a multiplication of maximum voltage by maximum
current rating values.
Unit
W
Query
[SOURce]:POWer[:LEVel]?
Return
<NR2> 5-digits format