STATus:OPERation:ENABle <NR1>
Function Sets the value of the Operational Condition Group Enable register. This
register is a mask for enabling specific bits from the Condition register to
the Event register. Refer to STATus:OPERation[:EVENt]? command for the
complete list of the registers that can be masked.
Parameters
0…65535
Query
STATus:OPERation:ENABle?
Returns
<NR1> 0…65535
STATus:QUEStionable[:EVENt]?
Query Returns the value of the Questionable Condition Group Event register. This is a read-
only register.
The value is according to the Questionable Condition Group Condition register and
Questionable Condition Group Enable register.
Events are updated as transition from 0 to 1. Reading the register clears it.
Bit configuration of the Questionable Condition Group Event register is as follows:
Position
Value
Name
Position
15
-
-
7
14
16384
POFF
6
13
-
-
5
12
-
-
4
11
2048
GERR
3
10
1024
PACK
2
9
512
UVP
1
8
256
ENA
0
Value
128
64
32
16
8
4
2
-
Name
ILC
OFF
SO
OVP
FLD
OTP
AC
-
POFF Power OFF.
Set to “1” when the Power Supply
Power Switch is OFF.
GERR General Error.
Unrecoverable system fault. Recycle
AC input.
PACK Parallel Acknowledge.
Acknowledge new parallel system.
Refer to section 6.9.
UVP Under Voltage Protection.
Set to “1” when Under Voltage
Protection fault occurs.
ENA Enable.
Set to “1” when Enable fault occurs.
ILC – Interlock.
Set to “1” when Interlock signal fault
occurs
OFF DC Output OFF.
Set to “1” when the Power Supply DC
output is OFF.
SO Shut OFF (Daisy In).
Set to “1” when Shut OFF signal is high.
OVP Over Voltage Protection.
Set to “1” when Over Voltage Protection
fault occurs.
FLD Foldback.
Set to “1” when Foldback fault occurs.
OTP Over Temperature Protection.
Set to “1” when Over Temperature
Protection fault occurs.
AC – AC.
Set to “1” when AC fault occurs.
Returns
<NR1> 0…65535
Example
00106