42
8303460000 Rev A IA672-04-01-Rev. I
Examples: VOLT:PROT:LEV 70
:VOLT:PROT:LEV MAX
Query: VOLT:PROT:LEV? will return 70 in the example
Errors: SYSTEM:ERROR? may return errors including:
+304,”OVP below PV”
-222,”Data out of range”
11.5.2. Read Over-Voltage Tripped
This query reports if an over-voltage protection fault has occurred. If a fault has
occurred, it may be cleared by turning the power supply output on again (see the
OUTP:STAT ON command, section 11.2.3)
Syntax: [SOURce:]VOLTage:PROTection:TRIPped?
Example: VOLT:PROT:TRIP?
Responses: 0 when no OVP fault is active
1 when supply is shut-down because of an OVP fault
11.5.3. Set Under-Voltage Limit
The under-voltage limit keeps the voltage setting from being less than a certain value.
If the actual power supply output (or remote sense point) drops below the UVL, no
fault is reported and the supply continues to operate in the constant-current mode
(you may use the foldback protection to report a fault when this occurs, see section
11.5.5)
The voltage limit setting, made by the front panel encoder or the VOLT command (in
section 11.2.1), must always be higher than 105% of the UVL setting. Likewise, the
UVL setting cannot be made higher than 95% of the voltage setting.
The UVL setting may be viewed on the supply front panel by pressing and releasing
the OVP/UVL button twice.
Syntax: [SOURce:]VOLTage:LIMit:LOW <nn.nn>
Parameter: nn.nn will set the UVL to a value in volts
Range is zero to 95% of the present voltage setting
Example: VOLT:LIM:LOW 5.100
Query: VOLT:LIM:LOW? will return 5.100 in the example
Errors: SYSTEM:ERROR? may return errors including:
+302,PV below UVL”
+306,”UVL above PV”
-222,”Data out of range”