EasyManua.ls Logo

TDK-Lambda Z+ series - Initiate Subsystem

TDK-Lambda Z+ series
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
101
DISPlay:STATus
Turns front panel voltage and current display toggle On or Off.
SCPI Command Syntax DISPlay[:WINDow]:STAT <bool>
GEN Command Syntax none
Parameters 0|OFF 1|ON
Examples DISP:STAT 1 DISP:STAT OFF
Query Syntax DISPlay[:WINDow]:STAT?
Returned Parameters 0 |1
DISPlay:FLASh
Makes front panel voltage and current displays flash.
SCPI Command Syntax DISPlay[:WINDow]:FLASh <bool>
GEN Command Syntax none
Parameters 0|OFF 1|ON
Examples DISP:FLASh 1 DISP:FLASh OFF
Query Syntax DISP:FLASh?
Returned Parameters 0 |1
7.12.7 INITiate Subsystem
INITate
[:IMMediate]
:CONTinuous <bool>
INITiate
Enables the trigger subsystem. If a trigger circuit is not enabled, all trigger commands are ignored.
SCPI Command Syntax INITiate[:IMMediate]
GEN Command Syntax None
Parameters None
Examples INIT:IMM
Query Syntax None

Table of Contents