98
VOLTage:PROTection:LOW
Sets the over voltage protection (UVP) level of the power supply.
SCPI Command Syntax [SOURce]:VOLTage:PROTection:LOW <NRf+>
GEN Command Syntax UVL < NRf+> , UVP < NRf+>
Default Suffix V
*RST Value 0
Examples VOLT:UNDer:PROT 2.5 VOLT:UNDer:PROT:LEV MAX
Query Syntax
[SOURce]:VOLTage:PROTection:LOW [:LEVel]?
VOLT:PROT:LOW? MIN; VOLT:PROT:LOW? MAX
Returned Parameters
<NR3> VOLT:PROT:UNDer? returns presently programmed UVP level.
VOLT:UNDer:PROT? MAX and VOLT:PROT:OVER? MIN return the maximum and
minimum programmable UVP levels.
NOTE:
VOLT:PROT:LOW MAX set UVP level maximum 5% below voltage value
VOLT:TRIG
Programs the pending triggered voltage level of the power supply. The pending triggered voltage
level is a stored value that is transferred to the output terminals when a trigger occurs.
SCPI Command Syntax [SOURce]:VOLTage[:LEVel]:TRIGgered [:AMPLitude] <NRf+>
GEN Command Syntax None
Default Suffix V
Examples VOLT:TRIG 1200 MV VOLT:LEV:TRIG 1.2
Query Syntax
[SOURce]:VOLTage[:LEVel]:TRIGgered [:AMPLitude]?
:VOLTage:TRIGgered? MAX; :VOLTage:TRIGgered? MIN
Returned Parameters
<NR3> VOLT:TRIG? returns the presently programmed voltage level. If the
TRIG level is not programmed, the IMM level is returned. VOLT:TRIG? MAX and
VOLT:TRIG? MIN return the maximum and minimum programmable triggered
voltage levels.
7.12.4 Current Subsystem
This subsystem programs the output current of the power supply.
CURRent
[:LEVel]
[:IMMediate]
[:AMPLitude] <NRf+> Set output Current
:TRIGger <NRf+> Set current value for trigger pending
:MODE <CRD> Select arbitrary trigger control mode