106
STATus:QUEStionable:ENABle
Sets the value of the Enable register. This register is a mask for enabling specific bits from the
Condition register to the Event register.
SCPI Command Syntax STATus:QUEStionable:ENABle <NRf>
GEN Command Syntax FENA nnnn
Parameters 0 to 32727
Returned Parameters <NR1> (Register Value) decimal
Default Value 0
Query Syntax STATus: QUEStionabl:ENABle?
Examples STAT:QUES:ENAB 18
7.12.10 SYSTem Subsystem
SYSTem
:ERRor:ENABle Enable Error Message
:ERRor? Read system error Error Messages
:LANGuage
:REMote
[:STATe] Set program mode “0|LOC”- Local, “1|REM” – Remote, “2|LLO”- Go to
Lockout
:VERSion Software revision
:DATE Calibration Date
:PON:TIME? Response time from last reset
SYSTem:ERRor:ENABle
Enables Error messages.
SCPI Command Syntax SYSTem:ERRor:ENABle
GEN Command Syntax None
Parameters None
Returned Parameters None
SYSTem:ERRor?
Returns the next error number and corresponding error message in the power supply error queue.
Works as FIFO. When no error exists 0, “No error” is returned.
SCPI Command Syntax SYSTem:ERRor?
GEN Command Syntax None
Parameters None
Returned Parameters <NR1>,<SRD>
Example SYST:ERR?