110
WAVE:STEP
WAVE:STEP AUTO - When triggered, creates waveforms consecutively, until the count is completed.
WAVE: STEP ONCE - When triggered, creates a waveform one time only.
SCPI Command Syntax [SOURce]WAVE:STEP AUTO|ONCE
Examples WAVE:STEP AUTO
Query Syntax [SOURce]:WAVE:STEP?
Returned Parameters AUTO | ONCE
WAVE:STORe
Stores Voltage or Current, Time, STEP parameter and counter values to specific location in the
memory defined by numbers <1..4>.
SCPI Command Syntax [SOURce]WAVE:STORe<NF1>
Examples WAVE:STORe 3
WAVE:TIME
Sets the slope time of the waveform.
SCPI Command Syntax [SOURce]:WAVE:TIME <NRf1> {,<NRf1>}
Range 0.01 to 65 |MINimum | MAXimum
Default Suffix S
Examples WAVE:TIME .6,1.5,1.5,.4 up to 12 parameters
Query Syntax WAVE:TIME?
Returned Parameters .6,1.5,1.5,.4
WAVE:VOLT
Specifies the output voltage points in a waveform list.
SCPI Command Syntax [SOURce]:WAVE:VOLTage <NRf+> {,<NRf+>}
Default Suffix V
Examples WAVE:VOLT 2.5,3.0,3.5 WAVE:VOLT MAX,2.5,MIN up to 12 parameters
Query Syntax WAVE:VOLT?
Returned Parameters MAX,2.5,MIN