TECDrive20-EU Series Inverter Function parameters
-74-
Function
code
Name
Description
Default
Modify
Refer to P00.11 and P00.12 for detailed
definition.
The first group of ACC/DEC time is the factory
default one.
Setting range: 0.03600.0s
P08.06
Jog running
frequency
This parameter is used to define the reference
frequency during jogging.
Setting range: 0.00HzP00.03 (the max.
frequency)
5.00Hz
P08.07
Jogging
running
acceleration
time
The jogging acceleration time means the time
needed if the inverter runs from 0Hz to the max.
frequency.
The jogging deceleration time means the time
needed if the inverter goes from the max.
frequency (P00.03) to 0Hz.
Setting range: 0.03600.0s
Depend
on
model
P08.08
Jogging
running
deceleration
time
P08.09
Jumping
frequency 1
When the set frequency is in the range of
jumping frequency, the inverter will run at the
edge of the jumping frequency.
The inverter can avoid the mechanical
resonance point by setting the jumping
frequency. The inverter can set three jumping
frequency. But this function will be invalid if all
jumping points are 0.
Set frequency f
Time t
Jump
frequency 2
1/2*Jump
frequency range 2
1/2*Jump
frequency range 2
Jump
frequency 1
1/2*Jump
frequency range 1
1/2*Jump
frequency range 1
Jump
frequency 3
1/2*Jump
frequency range 3
1/2*Jump
frequency range 3
Setting range: 0.00P00.03 (the max. frequency)
0.00Hz
P08.10
Jumping
frequency
range 1
0.00Hz
P08.11
Jumping
frequency 2
0.00Hz
P08.12
Jumping
frequency
range 2
0.00Hz
P08.13
Jumping
frequency 3
0.00Hz
P08.14
Jumping
frequency
range 3
0.00Hz
P08.15
Traverse range
This function applies to the industries where
0.0%