TECDrive20-EU Series Inverter Function parameters
-75-
Function
code
Name
Description
Default
Modify
P08.16
Sudden
jumping
frequency
range
traverse and convolution function are required
such as textile and chemical fiber.
The traverse function means that the output
frequency of the inverter is fluctuated with the set
frequency as its center. The route of the running
frequency is illustrated as below, of which the
traverse is set by P08.15 and when P08.15 is set
as 0, the traverse is 0 with no function.
Output frequency
Jumping frequency
Accelerate
Decelerate per
dec. time
Wobble frequency amplitude
Fall time of
wobble frequency
Rise time of
wobble frequency
Center
frequency
Lower limit of
wobble frequency
Traverse range: The traverse running is limited
by upper and low frequency.
The traverse range relative to the center
frequency: traverse range AW center
frequency×traverse range P08.15.
Sudden jumping frequency traverse range
AW×sudden jumping frequency range P08.16.
When run at the traverse frequency, the value
which is relative to the sudden jumping
frequency.
The raising time of the traverse frequency: The
time from the lowest point to the highest one.
The declining time of the traverse frequency: The
time from the highest point to the lowest one.
Setting range of P08.15: 0.0100.0%
(relative to the set frequency)
Setting range of P08.16: 0.050.0%
(relative to the traverse range)
Setting range of P08.17: 0.13600.0s
Setting range of P08.18: 0.13600.0s
0.0%
P08.17
Traverse boost
time
5.0s
P08.18
Traverse
declining time
5.0s
P08.19
Linear speed/
frequency
decimals
Ones place: decimals of linear speed display
0: no decimals
1: one decimal
2.: two decimals
3: three decimals
0x00