KINESIS ONE: Service & Maintenance Manual rev. 2.1
Page 8.4
8.2. EXTRA-ORDINARY MAINTENANCE OPERATIONS
8.2.1. CHECK THE PULLEYS
1. Check the wear status of the pulley grooves. Repair and/or replace any worn parts.
8.2.2. CHECK THE WEIGHT STACK ROD STOPS
1. Check the wear status of the weight stack rod stops. Repair and/or replace any worn parts.
2. Check the position of the weight stack rod stops and make sure they are firmly fastened in place.
8.2.3. REPLACING THE CABLES
1. Replace the machine cables once a year if the machines are used intensively, every 2 years
under normal use.
8.2.4. SCREW AND BOLT CHECK
1. Make sure that the screws and bolts are firmly tightened, especially in the weight stack and seat
adjustment areas, and around moving parts in general. Tighten any that are loose.
8.2.5. CHECKING FOR MECHANISM PLAY
1. Make sure that the machine mechanisms (pulleys assembly) have no play. Repair and/or replace
any worn parts.
8.2.6. CHECKING CROSS ALIGNMENT
1. Do not select any weight, and lift the cross. Make sure that the sinker is properly centred over
the plate hole, and that all plates in the weight stack may be selected without any strain on the
selection knob. Force it to the centre by hand.