EasyManua.ls Logo

TECO speecon 7200ma - Page 68

TECO speecon 7200ma
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
66
Function
Parameter
No.
Name
LCD display
(English)
Description
Factory
Setting
Ref.
Page
Sn-40
PG Speed
Control Function
Sn-40= 0
PG Invalid
0 : without speed control
1 : with speed control
2 : with speed control but no
inte
g
ration control durin
g
Acc/Dec.
3 : with s
p
eed control and inte
g
ration
control during Acc/Dec.
0 96
Sn-41
Operation
Selection At PG
Open Circuit
Sn-41= 0
1st. Dec. Stop
0 : deceleration to stop (Bn-02)
1 : coast to stop
2 : deceleration to stop (Bn-04)
3 : continue to run
0 96
Sn-42
O
p
eration Selection
At PG Lar
g
e S
p
eed
Deviation
Sn-42= 0
1st. Dec Stop
0 : deceleration to stop (Bn-02)
1 : coast to stop
2 : deceleration to stop (Bn-04)
3 : continue to run
0 96
PG S
p
eed
Control
Sn-43
O
p
eration Selection
At PG Overspeed
Detection Deviation
Sn-43= 0
1st. Dec. Stop
0 : deceleration to stop (Bn-02)
1 : coast to stop
2 : deceleration to stop (Bn-04)
3 : continue to run
0 96
Sn-44
O
p
eration Mode
Selection Durin
g
Auto_Run
Sn-44= 0
Auto
_
Run Invalid
0 : Auto_Run mode not effective
1 :Auto_Run mode for one single
cycle. (continuing running from
the unfinished step if restarting)
2 :Auto_Run mode be performed
periodically
(continuing running
from the unfinished step if restarting)
3 :Auto_Run mode for one single
cycle, then hold the speed of final
step to run.
(continuing running from
the unfinished step if restarting)
4 :Auto_Run mode for one single
cycle. (starting a new cycle if
restarting)
5 :Auto_Run mode be performed
periodically (starting a new cycle
if restarting)
6 :Auto_Run mode for one single
cycle, then hold the speed of final
ste
p
to run.
(
startin
g
a new c
y
cle if
restarting)
097
Sn-45
Auto_Run Mode
Operation Selection1
Sn-45= 0
Auto
_
Run Sto
p
0
Sn-46
Auto_Run Mode
Operation Selection2
Sn-46= 0
Auto
_
Run Sto
p
0
Sn-47
Auto_Run Mode
Operation Selection3
Sn-47= 0
Auto
_
Run Sto
p
0
Sn-48
Auto_Run Mode
Operation Selection4
Sn-48= 0
Auto
_
Run Sto
p
0
Sn-49
Auto_Run Mode
Operation Selection5
Sn-49= 0
Auto
_
Run Sto
p
0
Auto
_
Run
Mode
Sn-50
Auto_Run Mode
Operation Selection6
Sn-50= 0
Auto
_
Run Sto
p
0 : stop (Bn-02)
1 : forward
2 : reverse
0
97

Table of Contents