1Ć14
$&% ' "
Source Voltage and Frequency 90-132 VAC
RMS
continuous range for 48 through 440 Hz.
180-250 VAC
RMS
continuous range for 48 through 440 Hz.
Power Consumption 85 watts (150 VA).
$&% ' ! #
Third Party Certifications This product shall conform to and be certified where appropriate
according to the following requirements:
Underwriter's Laboratories (UL) Listed or Recognized
Component, Electrical and
Electronic Measuring and Testing
Equipment UL 1244.
Canadian Standards CSA
Association (CSA)
Category Certified Electronic
Development and Test
Equipment, CSA 22.2 no. 231.
SelfĆCertification International
ElectroĆTechnical Commission
(IEC)
SelfĆcertified by Tektronix to
comply with IEC 348
recommendation.
Temperature: Operating and
Nonoperating
Operating: -10_ Cto+55_ C.
Nonoperating: -51_ Cto+71_ C.
Humidity: Operating and Nonoperating To 95% relative humidity at or below +40_ C to 75% relative
humidity form +41_ Cto+55_ C.
A more sever test than stated in MIL-T-28800E, para. 4.5.5.1.1.2.
Altitude: Operating and Nonoperating Operating: To 4572 m (15,000 ft.).
Nonoperating: To 12192 m (40,000 ft.).
Random Vibration: Nonoperating 2.46 g
RMS
, from 5 to 500 Hz, 10 minutes each axis.
Random Vibration: Operating 0.31 g
RMS
, from 5 to 500 Hz, 10 minutes each axis.
Emissions The instrument meets or exceeds the EMC requirements of the
following standards:
H VFG 243.
H FCC Code of Federal Regulations, 47 CFR, Part 15, Subpart B,
Class A.
Electrostatic Discharge Susceptibility IEC 801-2.