p
Model 880 DEPOSITION CONTROLLER
y
SECTION 1.XX
e page 18 of 275 ^
Shutter Delay Mode N.A.
Shutter Delay TIMEOUT Film Parameter: Shutter Delay Mode = ON
Shutter Delay QUALITY Film Parameter: Shutter Delay Mode = ON
(XTAL) RATE SAMPLING N.A.
(XTAL) SAMPLE INTERVAL (Film Parameter: (XTAL) RATE SAMPLING = Timed
or
Film Parameter: (XTAL) RATE SAMPLING = Inteli)
(XTAL) SAMPLE DWELL TIME Film Parameter: (XTAL) RATE SAMPLING = Timed
(XTAL) SAMPLE QUAL Film Parameter: (XTAL) RATE SAMPLING = Inteli
(XTAL) SAMPLE ALARM TIME Film Parameter: (XTAL) RATE SAMPLING = Inteli
FILM Fail Mode N.A.
Control Loop Qual Limits N.A.
XTAL Stability S Limits N.A.
XTAL Life Bounds N.A.
Plot Vert Scale Volts N.A.
Plot Horiz Scale H N.A.
Data Plot Type N.A.
Source Sensor MAP SELECT N.A.
POCKET SELECT N.A.
ETCHING MODE N.A.
Main Menu value Dependency List:
Next Active Process (Select)
1
Service Menu: Sequence Able + Accept keys (for Sequencing Mode)
2
If N/A, must use START + Reset / Start Proc keys to start a process.
Next Active Film (Select)
1
Service Menu: Non-Sequence + Accept keys (Non-Sequencing Mode)
2
Review Process (Select) Service Menu: Sequence Able + Accept keys (for Sequencing Mode)
2
Review Film (Select) N.A.
Review Source/Sensor Map (Sel)
N.A.
[NOTE
1
: press to invoke number entry submenu, sequence of 1 or 2 digits is entered or discarded]
Note
2
: [the Seq Able / Non Seq key shows the current mode upon entry into the
Service menu, changing the mode toggles key text and generates the Accept
key that in turn needs to be pressed to accept new mode described on the key
in text]
RunTime Screen parameter Dependency List:
(Crystal Quality Indicator Select) L/Q, Loop x, Qual xx Film Parameters
(Crystal Sample Select) Film Parameter: (XTAL) Rate Sampling = Timed or Intelligent?
Running in deposit mode
(Crystal Select) System Config Parameter: Need Source/Sensor Card X
Review Source Sensor Map Element Parameters:
Minimum Start Xtal Channels
Minumum Active Xtal Channels
Channel X Start Mode
(Process X) Main Menu Parameter: [Next Process] Digit
Fixed Front Panel START key: sequence from N/A to 1
Service Menu: SEQuence enABLE
[sequencing mode]
Layer X (layer = step) Review Processes X: EDIT: CHANGE, INSERT, DELETE
Layers/steps
Service Menu: SEQuence enABLE
[sequencing mode]
FILM Review Processes X: EDIT: CHANGE, INSERT, DELETE films
[sequencing mode]
Review Film X:
[non-sequencing mode]
(Manual mode) Running Process + Pressing fixed front panel MANUAL key +
attached Pendent