Model 880 DEPOSITION CONTROLLER
y
SECTION 1.XX
e page 17 of 275 ^
I/O Function elements:
[Menu end point: I/O Setup Menu path: Main/Executive menu/ I/O Setup]
I/O Relay Functions user I/O program
(8 Form C Relays per card [4 slots available for I or O cards])
I/O Input Functions user I/O program + PCB jumpers
(8 Inputs per card [4 slots for I or O cards])
I/O Setup Memory: save/swap, Operate: run/stop
I/O Programming Edit (Program): IN, NOT, AND, OR, XOR, POSitive, NEGative,
OUT, TRiP, SET, CLeaR, ARM, DRoP, (events/states/logical
operators), (softnodes) and (numeric elements).
Arithmetic operators/elements: KON# (to input constants), ADD,
SUBtract, MULtiply, DIVide, MODulus, EQUals, GReaTer than,
LESs than, and SELect. Editing: backspace, left/right arrows (to move
cursor), delete, undo, insert/delete line.
(Front Panel LEDs [4 discrete]) I/O programming elements (see table x in section 5xx and Section 2.2)
(User Front Panel Keys [4]) I/O programming elements (see table x in section 5xx and Section 2.2)
Pendent Keys (beyond specified Manual Mode use: I/O programming elements
[see table xxx in section 5xx ])
Service Menu values:
[Menu end point: Service Menu path: Main/Service]
(Test Mode Select) Test Off, Test On [Test Mode won't remain in effect if power is cycled)
(Seq/Non-seq Mode Select) Seq(uencing Mode Select en)able, Non-seq(uencing Select enabled)
(Memory Contents) as is (no modification), purged, factory (defaults) [see section x.2.2xx ]
(Reset) Arm reset, reset armed [Provide a product reset when back panel power
switch is not accessible. Also, use to generate ACCEPT key if not
present (e.g. to end the Test mode when in the Test mode).]

<<< move the following depenency lists to end of section 2.22? >>>
[Prerequisite states that must be in effect for the following parameters to be fully functional]
Film Parameter Dependency List:
Material Density Not Applicable
Material Z-Factor N.A.
Setpoint Thickness Limit N.A.
Final Thickness Limit (Trigger) Service Menu Parameter: Non Seq / Accept (Bug: 2
nd
µP not reset)
Setpoint Time Limit N.A.
Soak 1 Power level Value N.A.
Power Ramp 1 Time (to pwr level) N.A.
Power Soak 1 Time (@ pwr level) N.A.
Soak 2 Power level Value N.A.
Power Ramp 2 Time (to pwr level) N.A.
Power Soak 2 Time (@ pwr level) N.A.
Soak 3 Power level Value N.A.
Power Ramp 3 Time (to pwr level) N.A.
Deposit Rate (requested) N.A.
Rate Ramp Mode N.A.
New Deposit Rate Value Film Parameter: Rate Ramp Mode = ON
Rate Ramp Time Duration Film Parameter: Rate Ramp Mode = ON
Rate Ramp (Thickn) Trigger Point Film Parameter: Rate Ramp Mode = ON
Control Loop –Proportional term- N.A.
Control Loop –Integral term- N.A.
Control Loop –Derivative term- N.A.
Max Power Limit N.A.
Abort Max Power SW N.A.
Max Power Dwell Film Parameter: Abort Max Power SW = ON