EasyManua.ls Logo

Terex RT700 - Pump Troubleshooting

Terex RT700
404 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TROUBLESHOOTING
FAILURE OF PUMP TO DELIVER FLUID
CAUSE REMEDY
Pumps not engaged................................................................................Engage pumps.
Low fluid level in reservoir...................................................................Add recommended oil and check level.
Oil intake suction filter plugged............................................................Clean filter.
Air leak in suction line, preventing priming or causing
noise and irregular action of control circuit ..........................................Repair leaks.
Oil viscosity too heavy to pick up prime...............................................Use lighter viscosity oil. Follow recommendation for
temperatures encountered.
Broken pump shaft or parts broken inside pump ..................................Contact your local distributor; if necessary, refer to
the manufacturer’s manual for the correct instruc-
tions in pump disassembly and repair.
NO PRESSURE IN SYSTEM
CAUSE REMEDY
Pumps not engaged................................................................................Engage pumps.
Pump not delivering oil for any of
the reasons listed previously .................................................................Follow remedies given previously.
Relief valve not functioning due to:
Valve setting not high enough...............................................................Increase pressure setting of valves.
Valve leaking.........................................................................................Check seat for score marks and reseat.
Spring in relief valve broken.................................................................Replace spring and readjust valve.
Internal leakage in control valves or cylinders......................................To determine location, progressively block off vari-
ous parts of circuit. When trouble is located, repair.
(Do not block between pump and relief valve).
SWING CIRCUITPUMPS
RT700 Series Page 5 - 21 Issued: August 2003