TABLE 34 MINIMUM BREAKING FORCE
OF
WIRE
ROPE
7 x 7
and
7 x 19 Small Diameter Specialty Cord, Galvanized
and
Corrosion Resistant
Nominal
Approximate
Minimum
Breaking
Force***
Diameter
Mass
Galvanized
Corrosion
Resistant
7x7
7 x
19
7x7
7 x
19
7x7
7 x
19
IbsJ
kg/
lbs./
kg.!
inches
mm
100ft
30.5m**
100ft
30.5m**
lb
kg
lb
kg
Ib
kg
lb
kg
1132
.8
.16*
.07*
110*
49.9*
110*
49.9*
3/64 1.2
.42
.19
270
122
270
122
1/16
1.6
.75
.34
.75
.34
480
218
480
218
480
218
480
218
5/64
2.0
1.1
.50
650
295
650
295
3/32
2.4
1.6
.73
1.7
.77
920
417
1000
454
920
417
920
417
7/64
2.8
2.2
1.0
1260
572
1260
572
118
3.2
2.8
1.3
2.9
1.3
1700
771
2000
907
1700
771
1760
798
5/32
4.0
4.3
2.0
4.5
2.0
2600
1179
2800
1270
2400
1089
2400
1089
3/16
4.8
6.2
2.8
6.5
2.9
3700
1678
4200
1905
3700
1678
3700
1678
7/32
5.6
8.3
3.8
8.6
3.9
4800
2177
5600
2540
4800
2177
5000
2268
114
6.4
10.6
4.8
11.0
5.0
6100
2767
7000
3175
6100
2767
6400
2903
9/32
7.1
13.4
6.1
13.9
6.3
7600
3447
8000
3629
7600
3447
7800
3538
5/16
7.9
16.7
7.6
17.3
7.8
9200
4173
9800
4445
9000
4082
9000
4082
11/32
8.7
20.1
9.1
20.7
9.4
11,100
5035
12,500
5670
10,500
4763
3/8
9.5
23.6
10.7
24.3
11.0
13,100
5942
14,400
6532
12,000
5443
12,000
5443
*3 x 7 construction
**30.5m = 100 ft
***
To
convert to Kilonewtons (leN), multiply tons (minimum breaking force) by 8.896;
1
Jb
= 4.448 newtons (N).
Wire Rope Technical Board - Wire Rope Users Manual, Fourth