5.5. Instrument diagnosis
Important operating data and instrument data are displayed. A gas
path check (testo 330-2 LL) can be carried out. The status of the
sensors and any Error Services not yet rectified can be displayed.
Calling up the function:
or
> [ i ].
Carrying out a gas path check (testo 330-2 LL)
1. Gas Path Check [OK]
2. Place the black sealing cap on the tip of the flue gas probe.
- The pump flow is displayed. If the volumetric flow rate is less
than 0.02 l/min, the gas paths are not leaking.
3. End of check: [OK].
Viewing Error Services:
> Error Diagnosis [OK].
- Unrectified failures are displayed.
> View next / previous failure: [▲], [▼].