6 Using the product
53
Possibly:
> Enter the password: [Enter] → Enter password → [Next]
[OK].
- Gas zeroing (30 s).
Performing recalibration / adjustment:
WARNING
Dangerous gases
Danger of poisoning!
> Observe safety regulations / accident prevention regulations
when handling test gas.
> Use test gases in well ventilated rooms only.
1. Connect the calibration adapter to the flue gas socket.
2. Select the measurement parameter: [▲], [▼] [OK].
3. [Edit] → Enter the test gas concentration (val. nom.).
4. Attach the connecting line of the test gas bottle to the
calibration adapter.
5. Apply test gas to the sensor.
6. Start recalibration: [Start].
7. Accept the val. nom. once the act. val. is stable (adjustment):
[OK].
-or-
Abort (no adjustment): [esc].
8. Save changes: [Finished].
6.1.4. Fuels
The fuel can be selected. The fuel-specific coefficients and set
limits can be set.
Apart from the pre-configured fuels, 10 more customer specific
fuels can be configured. Fuel parameter, see
www.testo.com/download-center (registration required).
In order to maintain the measuring accuracy of the
instrument one must choose or configure the correct fuel.
The set limits serve the purpose of configuring the ideal
array of the flue gas matrix and do not have any influence
on the accuracy of the measuring results.