ACKF01_GB_00 TEXA S.p.A. 94/122
6.6 Flushing systems with orifice tube
6.6.1 Flushing the evaporator side
In order to prevent particles from the faulty compressor contaminating the rest of the system;
start flushing towards the accumulator location in the regular flow of the A/C system.
Connect the Konfort unit to system as following:
(1)Konfort red service hose with HP coupler to the orifice tube location
(2)Canister red service hose 3/8’’ SAE P/N 3900171 to the accumulator location
Accumulator
location
Orifice tube
location
(1)
(2)
Condenser
Evaporator