Table 6-3. Signal Descriptions (continued)
FUNCTION
SIGNAL
NAME
PIN NO.
(1)
PIN TYPE
(2)
DESCRIPTION
64 PM
48 PT,
RGZ
32
RHB
28
DGS28
Timer
(continued)
TIMA_FAL0
22
30
35
46
3
12
46
10
30
1
13
I Advanced control timer 0 fault handling input
TIMA_FAL1
19
33
45
64
1
11
41
1
9
4
12
I Advanced control timer 1 fault handling input
TIMA_FAL2
27
31
34
2
47
2
31
2
5
I Advanced control timer 2 fault handling input
UART
UART0_TX
33
35
47
56
1
3
18
1
14
4
15
O UART0 transmit data
UART0_RX
34
39
48
57
2
5
19
2
15
5
16
I UART0 receive data
UART0_CTS
7
16
27
55
17
29
38
13
18
14
17
I UART0 "clear to send" flow control input
UART0_RTS
8
28
54
16
30
12
19
18 O UART0 "request to send" flow control output
UART1_TX
10
52
54
58
16
20
32
12
21
20 O UART1 transmit data
UART1_RX
11
53
55
59
17
21
33
13
22
14
21
I UART1 receive data
UART1_CTS
17
50
60
14
22
39
25 24 I UART1 "clear to send" flow control input
UART1_RTS
18
51
61
15
23
40
26 25 O UART1 "request to send" flow control output
UART2_TX
3
14
17
24
25
36
39
43
25
27
24
26
O UART2 transmit data
UART2_RX
4
15
18
25
26
37
40
44
26
28
25
27
I UART2 receive data
UART2_CTS
37
43
50
58
9
14
20
7 10 I UART2 "clear to send" flow control input
UART2_RTS
36
44
51
59
10
15
21
8 11 O UART2 "request to send" flow control output
www.ti.com
MSPM0G3507, MSPM0G3506, MSPM0G3505
SLASEX6A – FEBRUARY 2023 – REVISED JUNE 2023
Copyright © 2023 Texas Instruments Incorporated
Submit Document Feedback
25
Product Folder Links: MSPM0G3507 MSPM0G3506 MSPM0G3505