Premier 412/816/832 Installation Manual Installation
INS159-13 15
Zone Connections
Each zone on the system is fully programmable to allow for
maximum flexibility (see page 25 for Zone Programming details).
The program options for a zone will also determine how the zone
may be wired. The following wiring options are available:
Type
Zone Status
Response
Normally Closed
< 10K
Secure
> 10K
Active
Normally Open
< 10K
Active
> 10K
Secure
Single EOL - N/C
& N/O (Burglary)
< 1K
Active
1K - 4.7K
Secure
> 4.7K
Active
Single EOL - N/O
(Fire)
< 1K
Active
1K - 4.7K
Secure
> 4.7K
Trouble
Single EOL - N/C
< 2K
Trouble
1K - 4.7K
Secure
> 4.7K
Active
Single EOL - O/C
Tamper
< 1K
Secure
1K - 4.7K
Active
> 4.7K
Tamper
Single EOL - S/C
Tamper
< 1K
Tamper
1K - 4.7K
Secure
> 4.7K
Active
Double EOL
< 1K*
Tamper
1K - 4K*
Secure
4K - 20K
Active
> 20K
Tamper
Zone Doubled
< 1K
Zones A & B Trouble
1K - 2K
Zones A & B Secure
2K - 4K
Zone A Violated
4K - 6K
Zone B Violated
> 6K
Zones A & B Violated
Triple EOL
< 1K*
Tamper
1K - 4K*
Secure
4K - 6K
Trouble (Fault)
6K - 8K
Active
8K - 20K
Trouble (Masked)
> 20K
Tamper
* This value may vary depending on the country code variant.
Normally Closed
Use this wiring configuration when connecting normally closed
detection devices to the zone. Ensure that the zone is programmed
for Normally Closed operation (see page 27). The zone must be
wired as follows:
Normally Open
Use this wiring configuration when connecting normally open
detection devices to the zone. Ensure that the zone is programmed
for Normally Open operation (see page 27). The zone must be wired
as follows: