EasyManua.ls Logo

Texecom Premier 816 - Communicator Options; ARC 1 Communicator Menu; Telephone Numbers

Texecom Premier 816
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming the Control Panel Premier 412/816/832 Installation Manual
52 INS159-13
etore Canne
> 12345678 <



Oen/Coe Can.
> ***4**** <

Cane >




d
b@
e
b
@
e
b
@
e
Communicator Options 
The on-board digital communicator/modem has the following
options:
 Enable On-Board Communicator
On: The on-board digital communicator will report system events
to the Alarm Receiving Centre.
Off: The communicator will not report system events.
 Enable DTMF Dialling
On: The on-board digital communicator will dial using DTMF (Dual
Tone Multiple Frequency) format.
Off: The communicator will dial using the older pulse format.
 Switch to Pulse Dialling After 3
rd
Attempt
On: The communicator will switch to the pulse dialling format after
failed 3
rd
attempt.
Off: The communicator will always dial using DTMF format.
Only applicable if Communicator Option 2 is enabled.
 Enable European Pulse Dialling
On: The communicator will dial using the European pulse dialling
timing ratios.
Off: The communicator will dial using US pulse dialling ratios.
Only applicable if Communicator Option 2 is disabled.
 Enable Auto Test Transmission
On: The communicator will send a periodic test transmission to
the Alarm Receiving Centre. See page 35 to alter the Test
Transmission Interval
Off: The communicator will not send test transmissions.
 Enable Cancel Call Waiting
On: The communicator will dial the Cancel Call Waiting sequence
before dialling the monitoring station.
Off: The communicator will not dial the Cancel Call Waiting
sequence.
 Enable Backup to Alarm Receiving Centre
On: The communicator will always report to Alarm Receiving
Centre 1, then make a backup report to Alarm Receiving
Centre 2.
Off: The communicator will initially attempt to report to Alarm
Receiving Centre 1. If for any reason the communicator fails
after using all its attempts, the communicator will attempt to
report to Alarm Receiving Centre 2.
 Enable Blind Dialling
On: The communicator will NOT look for a dial tone before dialling
the telephone number.
Off: The communicator will wait for the dial tone before attempting
to dial out.
ARC 1 Communicator Menu 
The ARC 1 Communicator Menu has the following options:
Primary and Secondary Telephone Numbers
Account Numbers
Protocol Type
Dial Attempts
Partition Options
Reporting Options
Pulse Format Options
Fast Format Reporting Channels
Protocol Options
Telephone Numbers -
Alarm Receiving Centre 1 has a primary and secondary telephone
number. The primary number is the number that is dialled first and if
programmed the secondary telephone number is a backup number
for the primary number. If both numbers are programmed the panel
will alternate between them when dialling the alarm receiving centre.

Table of Contents