Specifications Premier 412/816/832 Installation Manual
78 INS159-13
6. Specifications
Control Panel
All Models Large & Small Polymer
Current
Current Consumption
50mA
Maximum Current Available
0.3A charge
1.1A
Rated Output
Battery
Arrangement
Battery
Charge
Rated Output (Amps)
12h
1 x 7Ah
0.3A
0.533A
Standby and Recharge Times
EN50131-1
Grade 1
Grade 2
Minimum Standby Period
12h
12h
Maximum Recharge Time
72 Hrs
72 Hrs
Control Panel
Power Supply
Type A
Rated Input:
100V - 240V @ 50/60Hz; 1A
Rated Output Current @ 55°C::
1.5A MAX
Rated Output Voltage:
13.7Vdc +/- 2%
Mains Terminal Block Fuse:
250Vac; 3-3.15A Slow/Medium Blow
Maximum rating of each power output (note that these are not considered to
be "independent power outputs" according to EN50131-6
Aux 12V
Siren
Network
Battery
1.0A
1.0A
1.0A
2.5A
Standby Current
50mA
Output Voltage Range:
13.0V to 13.9V
Maximum Ripple Voltage:
0.5V pk-pk
Battery type:
sealed lead acid, up to 7Ah, Maximum
recharge time 72h
Battery Low Voltage Signal:
10.5V
Deep Discharge protection:
8.0V
Fuses (Electronic PTC)
F1 (2.5A) Battery Fuse
F2 (900mA) Auxiliary 12V power fuse
F3 (900mA) Siren/Bell output fuse
F4 (900mA) Network fuse
Housing (Polymer)
3mm Polycarbonate
Dimensions (Small) (W x H x D)
282mm x 225mm x 80mm
Dimensions (Large) (W x H x D)
305mm x 263mm x 98mm
Battery Compartment
One 12V 7.0Ah battery
Packed Weight
1.2 - 1.5 Kg (Approx)
All Models Metal
Current
Current Consumption
50mA
Maximum Current Available
0.3A charge
1.0A
0.75A charge
1.9A
Rated Output
Battery
Arrangement
Battery
Charge
Rated Output (Amps)
12h
24h
30h
60h
1 x 7Ah
0.3A
0.533A
0.241A
0.183A
X
1 x 17Ah
0.3A
1.36A
0.658A
0.516A
0.233A
0.75A
1.0A
0.658A
0.516A
0.233A
Standby and Recharge Times
EN50131-1
Grade 1
Grade 2
Minimum Standby Period
12h
12h
Maximum Recharge Time
72 Hrs
72 Hrs
Jumper Settings
Battery Arrangement
Recharge Time
Charge Selection
1 x 7Ah
< 24Hrs
0.3A
1 x 17Ah
< 24Hrs
0.75AA
< 72Hrs
0.3A
Control Panel
Rated Input:
Rated Output Current@40°C:
220V - 240V @50/60Hz; 1A
2.5A MAX
Rated Input:
Rated Output Current@40°C:
100VV - 120V @50/60Hz; 1A
2.3A MAX
Rated Output Voltage:
13.7Vdc +/- 2%
Mains Terminal Block Fuse:
250Vac; 3-3.15A Slow/Medium Blow
Rated Input:
Rated Output Current@40°C:
220V - 240V @50/60Hz; 1A
2.5A MAX
Maximum rating of each power output (note that these are not considered to
be "independent power outputs" according to EN50131-6
Aux 12V
Siren
Network
Battery
1.0A
1.0A
1.0A
2.5A
Standby Current
50mA
Output Voltage Range:
13.0V to 13.9V
Maximum Ripple Voltage:
0.5V pk-pk
Battery type:
sealed lead acid, up to 7Ah, Maximum
recharge time 72h
Battery Low Voltage Signal:
10.5V
Deep Discharge protection:
8.0V
Fuses (Electronic PTC)
F1 (2.5A) Battery Fuse
F2 (900mA) Auxiliary 12V power fuse
F3 (900mA) Siren/Bell output fuse
F4 (900mA) Network fuse
Housing (Metal)
1mm Steel
Dimensions (W x H x D)
315mm x 415mm x 100mm
Battery Compartment
Up to One 12V 18Ah battery
Packed Weight
4.0Kg (Approx)
All Models
Electrical
Current Consumption
Quiescent Current:
Alarm:
<50mA
<150mA
Zones
Number:
EOL Resistor Value:
8
3K3
Panel Outputs
O/P 1 - Supervised:
O/P 2 - Supervised:
O/P 3 - 8:
1A switched to 0V
1A switched to 0V
100mA switched to 0V
Siren Output (Supervised)
Speaker Mode:
Bell Mode:
Minimum load 4
1A switched to 0V
2-Wire Smoke Detectors:
ESL429CT
System Sensor 2100TS
Onboard Communicator
Protocols:
Pulse Format, Express Format, Fast
Format, Contact ID, SIA Level 2/3,
Pager and Mobile Phone
Dialling Formats:
REN:
Approval:
Pulse or DTMF
1
CTR21, DPT-TE-001
Non Volatile Memory Component
412, 412 Plus, 816, 816 Plus:
832
24LC128
24LC256
EN50136-1-1 & EN50136-2-3
The inbuilt communicator complies with the requirements of EN50136-2-3 ,
EN50136-1-1 and are suitable for use in systems designed for use with ATS
levels 1 or 2 and environmental class 1 or 2 i.e. systems using notification
options up to and including 2B. With the PSTN functioning normally, the ATS will
comply with the required performance levels subject to the ARC being suitably
equipped.
These units may be used for Downloading, Remote Servicing or
SMS text messaging purposes in systems at ALL security
grades.
Environmental
Operating Temperature:
-10C to +55C
+14F to +131F
Maximum Humidity:
95% non-condensing
EMC Environment:
Residential/Commercial/Light
Industrial or Industrial

Table of Contents