Installation Premier 412/816/832 Installation Manual
18 INS159-13
Triple EOL wiring can only be used on remote keypads and
remote expanders that are fitted with V7.1 software or
above..
Double Pole
This wiring configuration can only be used on the Premier
LCD/LCDL remote keypads. It provides monitoring for alarm and
tamper using normally closed detection devices. Ensure that the
zone is programmed for Double EOL operation (see page 27). The
zone must be wired as follows:
2-Wire Smoke Detector
Compatible 2-wire smoke detectors such as the ESL429AT or
System Sensor 2100TS can be connected as shown:
Panel Output 1 must be enabled for 2-wire smoke detection
(see page 36 for details).
The jumper link fitted across JP1 (Enabled 2-Wire Smoke
Det.) MUST be removed.
The maximum number of detectors is 20.
Speaker/Bell Connections
The Siren/Spk output terminals on the main PCB can be configured
for Speaker or Siren/Bell operation.
Speaker Operation
When configured as speaker operation the output can be used for
driving 8 or 16 Ohm loud speakers as shown:
The Siren/Spk output must be enabled for speaker driver
(see page 36 for details).