System Timers 
These timers control the system timing and delay functions. The
function of each timer is described as follows:
 AC Fail Delay
This timer delays the audible indication following a mains (AC)
failure.
 Telephone Line Fault Delay
This timer delays the audible indication following a telephone line
fault.
 Cross Zone Time Window
If one or more zones have been programmed with ‘Enabled Cross
Zoning’, the system will only generate a verified cross zone alarm if
the zones are violated within this time window.
 Zone Soak Test Time
This timer controls the number of days a zone is put on soak test. If
a zone is violated during the soak test period it will not cause an
alarm, however, the event will be logged and the zone that failed
test will be indicated when the user disarms the system. The Zone
Soak Test is started when one or more zones are programmed with
‘Enable Soak Test’ attribute, see page 28. All zones that are on test
are removed from test at the end of the soak test period, providing
no failures have occurred.
 Restore Reporting Delay
This timer controls the delay between a system event restoring and
the system reporting the restore condition to the Alarm Receiving
Centre.
 Output Short Pulse Time
If output is programmed with the ‘Use Short Pulse Time’ attribute
the output will activate for the duration of this timer, 001 to 255 x
100mS.
 Zone Loop Response Time
If a zone is programmed with the ‘Quick Response Time’ attribute
the zone loop response will be controlled by the duration of this
timer, 001 to 255 x 8mS.
 Transmission Abort Delay
This timer controls the duration in which an alarm transmission may
be aborted following alarm activation. When an alarm occurs, the
‘Alarm Cancel’ condition is only reported if the system is disarmed
within this period. If the system is disarmed after this period the
‘Alarm Cancel’ is NOT reported.
 Test Transmission Interval
This timer controls the interval of test transmissions to the alarm
receiving centre. 000 = Control Timer 3; 024 = daily; 168 = weekly
etc. Enable Auto Test Transmission om page 52 must be ON,