Programming the Control Panel Premier 412/816/832 Installation Manual
32 INS159-13
 Enable Remote Disarming
On: The selected partition can be disarmed remotely via the
downloading computer.
Off: The selected partition cannot be disarmed remotely.
 Enable Local Exit Tones
On: When arming the selected partition only the keypad that is
being used will generate an exit tone.
Off: When arming the selected partition all keypads will generate
an exit tone.
 Stay Armed Entry is Instant
On: When the selected partition is Stay armed the entry/exit zone
changes to instant.
Off: When the selected partition is stay armed the entry/exit zone
is delayed.
 Stay Armed Exit is Delayed
On: The selected partition will provide an exit delay when being
Stay armed.
Off: The selected partition will arm instantly when being Stay
armed.
 Only Start Exit when Partition is Ready
On: When a user attempts to arm their partition, the system will
only allow the exit mode to start if the partition is Ready (all
zones secure).
Off: The system will allow the exit mode to start even if one or
more zones are violated. If one or more zones are violated,
the keypad will indicate the active zone(s) and generate a
fault tone. The active zones must be secured before the exit
time expires or the partition will not arm.
Partition Auto Arm/Disarm Options 
The system has four independent Control Timers that may be
configured to switch on and off at different points of the day and
days of the week (see page 36). One or more of these Control
Timers can be used to automatically Arm or Disarm a selected
partition:
 Auto Arm Partition with Control Timer 1
On: The selected partition is armed automatically when Control
Timer 1 is switched ON.
Off: The selected partition is not armed automatically.
 Auto Arm Partition with Control Timer 2
On: The selected partition is armed automatically when Control
Timer 2 is switched ON.
Off: The selected partition is not armed automatically.
 Auto Arm Partition with Control Timer 3
On: The selected partition is armed automatically when Control
Timer 3 is switched ON.
Off: The selected partition is not armed automatically.
 Auto Arm Partition with Control Timer 4
On: The selected partition is armed automatically when Control
Timer 4 is switched ON.
Off: The selected partition is not armed automatically.
When the control timer switches on, the panel will start a 2
minute exit timer. During the first 90 seconds of the exit timer
the panel will generate a warning tone every 10 seconds.
After which the panel will revert to a standard exit tone for the
remaining 30 seconds.
 Auto Disarm Partition with Control Timer 1
On: The selected partition is disarmed automatically when Control
Timer 1 is switched OFF.
Off: The selected partition is not disarmed automatically.
 Auto Disarm Partition with Control Timer 2
On: The selected partition is disarmed automatically when Control
Timer 2 is switched OFF.
Off: The selected partition is not disarmed automatically.
 Auto Disarm Partition with Control Timer 3
On: The selected partition is disarmed automatically when Control
Timer 3 is switched OFF.
Off: The selected partition is not disarmed automatically.
 Auto Disarm Partition with Control Timer 4
On: The selected partition is disarmed automatically when Control
Timer 4 is switched OFF.
Off: The selected partition is not disarmed automatically.
Equipment Areas 
This option allows you to assign the following to partitions:
 Auxiliary Input Areas
This option allows the Auxiliary input to be assigned to one or more
partitions. This will affect how the Auxiliary input now functions, e.g.
if the Auxiliary input is programmed as a “Latched Keyswitch” (see
page 38) and is assigned to partition 3 and 4, the system will arm
partitions 3 and 4 when the Auxiliary input is activated etc.
 Panel Bell Areas
This option allows the panel Bell output to be assigned to one or
more partitions. This will affect how the Bell output operates, e.g. if
the Bell output is assigned to partition 1 and 2, the panel Bell will
only activate when an alarm occurs in either partition 1 or 2.
 Bell Squawk Areas
This option allows the Bell Squawk feature to be assigned to one or
more partitions. This will effect how the Bell Squawk feature
operates, e.g. if the Bell Squawk feature is assigned to partition 1
and 2, the panel Bell output and any outputs programmed as Bell
will squawk when either partition 1 or 2 is armed/disarmed.
The Bell Squawk feature must also be enabled, see page 38.
 Masked when Armed
When a partition is assigned to this option, the system will generate
a full alarm if an Anti-Masking detector in the selected partition
reports a “Masking” condition whilst the selected partition is armed.
If the partition is unassigned, the system will only generate a “Zone
Trouble alarm”. The detector must be wired to the system using
Triple EOL wiring configuration, as shown on page 17.