Premier 412/816/832 Installation Manual Programming the Control Panel
INS159-13 29
Zone Attributes 3 (Key Switch) 
When a zone is programmed as a Key Switch type Zone Attributes 3
options 3, 4 and 6 are used to change the operation of the Key
Switch zone. The function of each attribute is described as follows:
 Key Switch is Instant Arming
On: The key switch zone will arm the selected partitions
immediately (no exit delay).
Off: The key switch zone will start exit timer for the selected
partitions.
 Key Switch will Stay Arm/Disarm
On: The key switch zone will Stay arm/disarm the selected
partitions.
Off: The key switch zone will Away arm/disarm the selected
partitions.
 Disable Auto Arm
On: When a key switch zone with this attribute is active, it will
disable the auto-arm feature for the partitions assigned to the
zone. When the zone returns to the secure state the auto-arm
feature is re-enabled.
Off: Keyswitch zones behave as normal.
 Monitor Only
On: Any Activation/deactivation from this zone will be logged and
reported to an ARC as a Keytube. There will be no notification
on any keypads or alarm.
Off: Keyswitch zones behave as normal.
Zone Partitions & Groups 
Partitions allow the system to be divided into areas of protection so
that different partitions can be armed and disarmed independently
from each other. By default all zones are assigned to Partition 1, but
if required a zone can be assigned to Partitions 1 - 4. If a zone is
assigned to more than one partition it will only be armed when all
partitions they are assigned to are armed.
The system has four Bypass Groups, these can be configured so
that the user can select a predefined group of zones for bypassing.
The function of each attribute is described as follows:
 Partition 1
On: The zone is assigned to Partition 1.
Off: The zone is not assigned to Partition 1.
 Partition 2
On: The zone is assigned to Partition 2.
Off: The zone is not assigned to Partition 2.
 Partition 3 (Premier 816/832 Only)
On: The zone is assigned to Partition 3.
Off: The zone is not assigned to Partition 3.
 Partition 4 (Premier 816/832 Only)
On: The zone is assigned to Partition 4.
Off: The zone is not assigned to Partition 4.
 Group 1 Bypass
On: The zone is assigned to Group 1 Bypass.
Off: The zone is not assigned to Group 1 Bypass.
 Group 2 Bypass
On: The zone is assigned to Group 2 Bypass.
Off: The zone is not assigned to Group 2 Bypass.
 Group 3 Bypass
On: The zone is assigned to Group 3 Bypass.
Off: The zone is not assigned to Group 3 Bypass.
 Group 4 Bypass
On: The zone is assigned to Group 4 Bypass.
Off: The zone is not assigned to Group 4 Bypass.
Zones must be assigned to at least one partition, if a zone is
not assigned to a partition it will not respond to any alarm
activation.
Zone Text (LCD Only) 
If the system is fitted with LCD remote keypad you can assign up to
16 characters of text to each zone. Text is programmed in a similar
way to mobile phones. Characters are selected by pressing the
corresponding key the appropriate number of times (to select a
character on the same key, press to move the cursor along).
For details on entering text, see page 22.
Assign Radio Device 
If the system is fitted with a Radioplus or Ricochet™ radio
module this menu option is enabled. This menu is used to assign
radio devices such as PIRs and Door Contacts to a zone on the
system. Radio devices can be assigned to any of the available
zones on the system.